I got most of these ideas from listening to other repeaters in my area. All macros work fine on my RLC1+ (v2.09) with a Doug Hall RBI The only thing I'all guarantee here is there is no virus in this file! :) I might also add that I had problems with the RLC1+ with my Master II Repeater until Allan at Link Talked me into changing my cor to active low, which is default for the controller. Feel free to edit and exchange pieces at will till it works for you. I would highly recommend that you understand each line and what it does before you do anything! Good Luck & 73's.....Greg (KC5WDV) ;Macro 1-141-courtesy beep 127 01 d ;erase macro 1 130 01 042 1064 0000 0015 000 d ;programs macro1 064 011 2 141 6 d ;assign court. beep Macro 1 port 1 ;Macro 2-142- pl-on 127 02 d ;clears macro slot 2 130 02 045 046 042 358 d;Speaks -pl on 130 02 131 d ;disable voice response 130 02 012 1 3 1 d ;access only with cor and pl ;Macro 3-143- pl-off 127 03 d ;Clears macro slot 3 130 03 045 046 042 354 d;Speaks -pl off 130 03 131 d ;disable voice response 130 03 012 1 1 1 d ;access only with cor ;Macro 4-144- Packet Off 127 04 d ;Clears macro slot 4 130 04 045 587 587 619 654 354 d;Speaks-pause,pause,digital radio off 130 04 131 d ;disable voice response 130 04 086 d ;Turns on output 1,packet disable ;Macro 5-145- Packet On 127 05 d ;clears macro slot 5 130 05 045 587 587 619 654 358 d;Speaks-pause,pause,digital radio on 130 05 131 d ;disable voice response 130 05 087 d ;Turns off output 1, Packet enable ;Macro 7-147- Intial id 127 07 d ;clears macro 7 130 07 048 01 d ;calls m slot 1 time 130 07 048 02 d ;calls m slot 2 cw id ;Macro 11-151-Normal Hang Time 130 11 131 d ;disable voice response 130 11 052 00 200 d ;sets port 1 hang timer at 2 seconds 130 11 052 10 060 d ;sets port 1 beep timer at .6 sec ;Macro 12-152-Short Hang time 130 12 131 d ;disable voice response 130 12 052 00 001 d ;set port 1 hang timer at 10ms 130 12 052 10 002 d ;sets port 1 beep timer at 20ms This helps keep the chatter down when a SAR mission is going on, you may want to add auto 10 min ids with event, port 1 ptt just went inactive ;Emergency Operation 049 09 1 701 587 118 180 360 733 d ;set m slot 9 "time,pause,cancel emergency operation" 049 03 1 701 587 180 360 733 d ;set m slot3-"time,pause, emergency operation" 064 019 1 003 1 d ;set event 019 request m slot 3 port 1 064 020 1 003 1 d ;Set event 020 request m slot 3 port 1 064 021 1 003 1 d ;Set event 021 request m slot 3 port 1 064 022 1 003 1 d ;set event 022 request m slot 3 port 1 061 01 15 d ;calls event 1 at 15 min after the hour 061 02 30 d ;calls event 2 at 30 min after the hour 061 03 45 d ;calls event 3 at 45 min after the hour 061 04 59 d ;calls event 4 at 59 min after the hour ;Macro 10-150-Enable Emergency Operation 127 10 d ;clears macro 10 130 10 048 03 d ;calls M slot 3 130 10 131 d ;responses off 130 10 065 019 1 d ;enable event 1 130 10 065 020 1 d ;enable event 2 130 10 065 021 1 d ;enable event 3 130 10 065 022 1 d ;enable event 4 130 10 152 d ;calls macro 12-short hang time ;Macro 9-149-Disable Emergency Operation 127 09 d ;clears macro 9 130 09 131 d ;response off 130 09 065 019 0 d ;disable event 1 130 09 065 020 0 d ;disable event 2 130 09 065 021 0 d ;disable event 3 130 09 065 022 0 d ;disable event 4 130 09 151 d ;calls macro 11-normal hang time 130 09 132 d ;response on 130 09 048 09 d ;call m slot 9 cancel emergency operation ;Configure inputs 070 1 06 d ;sets inside temp sensor to faceplate 6 070 2 06 d ;sets outside temp sensor to faceplate 6 070 3 12 d ;sets Battery Voltage to faceplate 12 072 1 1 06 d ;calibrates inside temp. sensor 072 2 1 06 d ;calibrates outside temp sensor 072 3 0 27 d ;calibrates Battery Voltage ;Marcos 13-153 & 14-154 Low Battery Voltage Alarm-Analog 3 082 3 0 105 d ;Sets Low Batt alarm at 10 volts 064 052 2 153 1 d ;alarm low calls macro 13 port 1 064 056 2 154 1 d ;alarm off calls macro 14 port 1 127 13 d ;clears macro 13 130 13 045 298 516 070 d;Speaks Low volts Alert 127 14 d ;clears macro 14 130 14 045 098 516 070 118 d;speaks-Battery volts alert cancel ;Macros 15-155 & 16-156 Inside Temp High Alarm-Analog 1 082 1 1 208 d ;Set analog 1 alarm at 127 f. 064 046 2 155 1 d ;Sets analog 1 high event to call macro 15 064 054 2 156 1 d ;sets analog 1 low event to call macro 16 127 15 d ;clears macro 15 130 15 045 245 469 070 d;Speaks-HIGH TEMP ALERT 127 16 d ;clears macro 16 130 16 045 245 469 070 118 d ;speaks-high temp alert cancel ;Macros 17-157 & 18-158 High Battery Voltage Alarm 082 3 1 151 d ;Sets high alarm at 14.8 volts 064 048 2 157 1 d ;Alarm high call macro 17 064 056 2 158 1 d ;Alarm off calls macro 18 127 17 d ;clears macro 17 130 17 045 245 516 070 d;speaks-High volts alert 127 18 d ;clears macro 18 130 18 045 098 516 070 118 d;speaks-Battery volts alert cancel ;Macros 19-159 & 20-160 AC power Failure 064 058 2 160 1 d ;sets input 1 low -call macro 20 -ac on 064 062 2 159 1 d ;sets input 1 high -call macro 19 -ac off 127 19 d ;clears macro 19 130 19 045 031 033 384 192 587 098 384 358 d ;set macro 19 speak-ac power failure pause battery power on 130 19 172 d ;Disconnect ports 1&2 130 19 131 d ;responses off 130 19 065 011 0 d ;Turns off port 1 beep 130 19 144 d ;Turns off packet radio 127 20 d ;clears macro 20 130 20 045 031 033 384 358 587 098 384 354 d ;set macro 20 speak-ac power on pause battery power off 130 20 131 d ;responses off 130 20 065 011 1 d ;Turns on port1 beep 130 20 145 d ;Turns on Packet Radio ;Message Slots for time-temp-battery 049 04 1 587 257 441 245 469 270 709 086 717 358 725 d ;Pause-Inside high temp at time on date 049 05 1 587 257 441 298 469 270 713 086 721 358 729 d ;Pause-Inside low temp at time on date 049 06 1 587 364 441 245 469 270 710 086 718 358 726 d ;Pause-Outside high temp at time on date 049 07 1 587 364 441 298 469 270 714 086 722 358 730 d ;Pause-Outside low temp at time on date 049 08 1 587 149 257 441 469 270 705 161 194 d ;Pause-Current Inside temp. is - degrees Far. 049 10 1 587 149 364 441 469 270 706 161 194 d ;Pause-Current Outside temp is - degrees Far. 049 11 1 587 149 098 270 707 516 d ;Pause-Current Battery is - volts 049 12 1 587 098 245 270 711 516 086 719 358 727 d ;Pause-Battery high is - volts at time on date 049 13 1 587 098 298 270 715 516 086 723 358 731 d ;Pause-Battery low is - volts at time on date ;Macro 21-161 Inside temp hi-low 127 21 d ;Clears Macro 21 130 21 048 04 d ;Calls m slot 4 130 21 048 05 d ;Calls m slot 5 ;Macro 22-162 Outside temp hi-low 127 22 d ;Clears Macro 22 130 22 048 06 d ;Calls m slot 6 130 22 048 07 d ;Calls m slot 7 ;Marco 23-163 Reset inside Hi-lo Temp 127 23 d ;Clears Macro 23 130 23 074 1 d ;resets hi-lo analog 1-inside sensor ;Macro 24-164 Reset outside Hi-lo temp 127 24 d ;Clears Macro 24 130 24 074 2 d ;resets hi-lo analog 2-outside sensor ;Macro 25-165 Current Inside-outside temps, battery volts 127 25 d ;Clears Macro 25 130 25 048 08 d ;Calls m slot 8 130 25 048 10 d ;Calls m slot 10 130 25 048 11 d ;Calls m slot 11 ;Macro 26-166 Battery hi-lo 127 26 d ;clears Macro 26 130 26 048 12 d ;Calls m slot 12 130 26 048 13 d ;Calls m slot 13 ;Macro 27-167 Battery Hi-lo reset 127 27 d ;Clears Macro 27 130 27 074 3 d ;reset analog 3 high-low -Battery volts ;Macro 28-168 Reset all Inputs 127 28 d ;Clears Macro 28 130 28 045 071 402 d ;Speaks-All Ready 130 28 131 d ;Disable voice response 130 28 163 d ;calls macro 163 130 28 131 d ;Disable voice 130 28 164 d ;calls macro 164 130 28 131 d ;disable voice 130 28 167 d ;calls macro 167 ;Macro 29-169 Inside-outside hi-lo 127 29 d ;clears Macro 29 130 29 161 d ;call macro 161 inside hi-lo 130 29 162 d ;calls macro 162 outside hi-lo ;Auto disconnect port 2 052 15 900 d ;Setup timer 1 for 15 min. 064 070 2 172 1 d ;user event 1 calls macro 172 when time out 064 040 2 171 1 d ;port 2 ptt calls macro 171 065 069 0 ;turns off ptt inactive timer ;Macro 30-170 Connect Remote Base 127 30 d ;Clears macro 30 130 30 131 d ;Disable responses 130 30 000 1 2 d ;Connects ports 1 2 130 30 065 070 1 d ;Enable user timer #1 event 130 30 065 040 1 d ;Enable port 2 active ptt reset timer ;Macro 31-171 Timer Reset 127 31 d ;Clears macro 31 130 31 131 d ;Cancels Responses 130 31 066 1 d ;Starts timer 1 ;Macro 32-172 Disconnect Remote Base 127 32 d ;Clears macro 32 130 32 045 292 354 d ;Speaks Link Off 130 32 131 d ;Cancels Responses 130 32 012 1 1 1 d ;Turns off pl 130 32 065 011 1 d ;Turns on port1 court. beep 130 32 002 1 2 d ;Disconnects ports 1 2 130 32 065 070 0 d ;Disable user Timer #1 event 130 32 065 040 0 d ;Disable port 2 ptt active timer reset 130 32 099 0 ;turn off radio ;Macro 33-173 Disable Auto-disconnect remote base timers 127 33 d ;Clears Macro 33 130 33 045 587 089 485 354 d ;Speaks Auto timer off 130 33 131 d ;Disable responses 130 33 065 070 0 d ;Disable user timer #1 event 130 33 065 040 0 d ;Disable port 2 ptt active timer reset ;Macro 41-181-43 Recieve on 127 41 d ;clears macro 41 130 41 151 d ;normal hang time 130 41 045 587 004 003 404 358 d ;Speaks 43 recieve on 130 41 131 d ;disable voice response 130 41 095 145430 0 d ;set frq. at 145.30 - 130 41 096 25 1 0 d ;set pl at 162.2 130 41 098 2 d ;set power on med. 130 41 001 1 2 d ;moniter port 2 ;Macro 42 182-43 Transmit on 127 42 d ;clears macro 42 130 42 045 587 004 003 497 358 d ;Speaks 43 Transmit on 130 42 142 d ;turns on pl 130 42 131 d ;disables voice response 130 42 065 011 0 d ;turns off port 1 court. beep.....i'am using other repeaters beep here lets locals know its linked, and to what. 130 42 170 d ;conects port 1-2,Enable timers ;Macro 43 183-Disconnect 43 127 43 d ;clears macro 43 130 43 045 587 004 003 408 354 d ;Speaks 43 Remote off 130 43 131 d ;disable voice response 130 43 172 ;disconect port 1 from port 2,Disable timers