;........................ ;: Analog Normal : ;: Uses macros 308-315 : ;:......................: ; ;-File Updated 16 Dec 1998. ; ! ;Get DTMF Prompt. ; n050 09 0 ;Mask ; ;Macro 316 - Analog 2/1 - Battery Voltage Normal. This will put the ;Controller back into normal operation. ; n053 316 038 ;Mask responces from now on. n056 316 057 601 268 ;Copy Macro 601 to 268 (Port 1 courtesy tones). n056 316 057 602 269 ;Copy Macro 602 to 269 (Port 2 courtesy tones). n056 316 057 603 270 ;Copy Macro 603 to 270 (Port 3 courtesy tones). n056 316 611 ;Call Macro 611. Reset Timers. n056 316 881 ;Call Macro 881, POCSAG Pager. See Pager.txt. n056 316 065 ;Unmask responces. n056 316 036 098 384 045 041 ;"Battery Power OK". ; ;Macro 611, Used for extra commands for Macro 308, Reset Timers. ; 053 611 020 074 300 ;Reset Time-out to 5mins. 056 611 020 075 300 ;Reset Time-out to 5mins. 056 611 020 076 300 ;Reset Time-out to 5mins. ; ;Macro 322 - Analog 2/7 - Current Normal. ; n053 322 884 ;Call Macro 884. ; ;Macro 323 - Analog 2/8 - Temperture Normal. ; n053 323 887 ;Call Macro 887. ; ;End Programming. ;